Title NCHRP Report 350 Assessment of Existing Roadside Safety Hardware
Record ID 75209
Personal Name
Creator
Buth, C. Eugene; Menges, Wanda L.; Schoeneman, Sandra K.
Personal Name
Contributor
McDevitt, Charles
Corporate Creator United States. Federal Highway Administration. Office of Safety and Traffic Operations Research and Development
Corporate
Contributor
Texas Transportation Institute
Publisher United States. Federal Highway Administration. Office of Safety and Traffic Operations
Publication Date 20001101
Language English
Abstract The Federal Highway Administration initiated this contract with the objective to crash test and evaluate several terminals, transitions, and longitudinal barriers to NCHRP Report 350. NCHRP Report 350 specifies crash tests and evaluation criteria for three performance levels for terminals and six performance levels for transitions and longitudinal barriers. The buried-in-backslope terminals evaluated were the G4 on steel posts and wood blockouts with a rub rail and a 6 to 1 vee ditch and the G4 with steel posts and wood blockouts with a 4 to 1 slope. Both met specifications for NCHRP Report 350 test 3-35. The 3-strand New York cable terminal was evaluated and met requirements for NCHRP Report 350 test 3-34. The transitions evaluated under this contract included the vertical wall transition (W-beam with W-beam rub rail and steel posts), the vertical flared back transition (W-beam with channel rub rail, steel posts, and routed wood blockouts), the Pennsylvania Department of Transportation (DOT) transition (vertical flared back concrete parapet with W-beam, rub rail, steel posts, and routed wood blockouts), the Nebraska thrie beam transition (vertical wall parapet with thrie beam), and the Connecticut W-beam transition (NJ-shape wall with W-beam and channel rub rail). All the transitions met the required criteria for NCHRP Report 350 test 3-21, except for the vertical flared back transition. The MB1 median cable barrier chosen for evaluation was the Washington State DOT (WSDOT) cable barrier with a New York cable rail terminal. The thrie beam guardrail with steel posts and routed wood blockouts and the strong wood post thrie beam guardrail were also evaluated. The cable barrier and both thrie beam guardrails met the required specifications for NCHRP Report 350 test 3-11. The modified thrie beam guardrail with 2.1-m-long W150x14 steel posts and W360x33 blockouts (Design No. SGR09b) was evaluated and met specifications for NCHRP Report 350 test 4-12. Construction details for all the terminals, transitions, and longitudinal barriers evaluated are reported herein. Also included are details of the crash tests performed and the assessment of each test.
Public Note Research Study Title: Assessment of Existing Roadside Safety Hardware - II; Contracting Officer’s Technical Representative (COTR): Charles F. McDevitt - HRDS-4
Rosap ID dot:49987
Rosap URL https://rosap.ntl.bts.gov/view/dot/49987
TRT Terms Guardrail terminals; Guardrails; Crash tests; Highway safety; Beams
General Subjects Terminals; Transitions; Longitudinal barriers; Cable barriers; Guardrails; Crash testing; Roadside safety
Geographical
Coverage
United States
TRIS Online
Accession No
1751341
Contract Number DTFH61-97-C-00039
Report Number FHWA-RD-01-042
Resource type Tech Report
URL https://ntlrepository.blob.core.windows.net/lib/75000/75200/75209/FHWA-RD-01-042.pdf
Format PDF